Axial play(measured under less than 4N axial force)
0.01¡«0.15mm
Maximum radial play
0.025mm
L:Maximum allowable screw depth into flange2.5mm
Motor data tested at ambient temperature 25 .Data varies when the temperature changes.
Operation outside stated limits may affect motor service life. Please consult us before doing so.
Motor service life depends on operating conditions. Under normal conditions, service life of 1000 to 3000 hours is achievable.
Excessive bending of motor terminals may result in breakage when more than 3 times.